Huawei S220-24T4X | Switch | 24x GE, 4x SFP+, AC
    SKU    
            S220-24T4X
            In stock
        
    HUAWEI S220-24T4X (24*10/100/1000BASE-T ports, 4*10GE SFP+ ports, built-in AC power) (S220-24T4X)
Categories: Default Category, Networking, Huawei, Data Center  & Cloud Services
        | Item | Specification | 
|---|---|
| Dimensions without packaging (H x W x D) [mm(in.)] | Basic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 220.0 mm (1.72 in. x 17.4 in. x 8.66 in.) Maximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 43.6 mm x 442.0 mm x 227.0 mm (1.72 in. x 17.4 in. x 8.94 in.) | 
| Dimensions with packaging (H x W x D) [mm(in.)] | 90.0 mm x 550.0 mm x 360.0 mm (3.54 in. x 21.65 in. x 14.17 in.) | 
| Chassis height [U] | 1 U | 
| Chassis material | Metal | 
| Weight without packaging [kg(lb)] | 2.32 kg (5.11 lb) | 
| Weight with packaging [kg(lb)] | 3.44 kg (7.58 lb) | 
| Typical power consumption [W] | 27.27 W | 
| Typical heat dissipation [BTU/hour] | 93.05 BTU/hour | 
| Maximum power consumption [W] | 35.04 W | 
| Maximum heat dissipation [BTU/hour] | 119.56 BTU/hour | 
| Static power consumption | 19.00 | 
| MTBF [years] | 70.75 years | 
| MTTR [hours] | 2 hours | 
| Availability | > 0.99999 | 
| Noise at normal temperature (acoustic power) [dB(A)] | 47 dB(A) | 
| Noise at normal temperature (acoustic pressure) [dB(A)] | 35 dB(A) | 
| Number of card slots | 0 | 
| Number of power slots | 0 | 
| Number of fans modules | 1 | 
| Switching capacity | To obtain data of this specification item, see the corresponding datasheet or contact the product sales personnel. | 
| Packet forwarding rate | To obtain data of this specification item, see the corresponding datasheet or contact the product sales personnel. | 
| Redundant power supply | Not supported | 
| Long-term operating temperature [°C(°F)] | -5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5905.44 ft.) | 
| Restriction on the operating temperature variation rate [°C(°F)] | When the altitude is 1800–5000 m (5906–16404 ft.), the highest operating temperature reduces by 1°C (1.8°F) every time the altitude increases by 220 m (722 ft.). Devices cannot start when the temperature is lower than 0°C (32°F). | 
| Storage temperature [°C(°F)] | –40°C to +70°C (–40°F to +158°F) | 
| Long-term operating relative humidity [RH] | 5% RH to 95% RH (non-condensing) | 
| Long-term operating altitude [m(ft.)] | 0–5000 m (0–16404 ft.) | 
| Storage altitude [m(ft.)] | 0-5000 m (0-16404 ft.) | 
| Power supply mode | AC built-in | 
| Rated input voltage [V] | AC input: 100–240 V AC; 50/60 Hz | 
| Input voltage range [V] | AC input: 90 V AC to 264 V AC; 45 Hz to 65 Hz | 
| Maximum input current [A] | 0.8 A | 
| Memory | 2 GB | 
| Flash memory | Physical space: 1 GB | 
| Console port | RJ45 | 
| Eth Management port | Not supported | 
| USB | Not supported | 
| RTC | Not supported | 
| RPS input | Not supported | 
| Service port surge protection [kV] | Common mode: ±7 kV | 
| Power supply surge protection [kV] | Differential mode: ±6 kV; common mode: ±6 kV | 
| Ingress protection level (dustproof/waterproof) | IP20 | 
| Types of fans | Built-in | 
| Heat dissipation mode | Air cooling for heat dissipation, intelligent fan speed adjustment | 
| Airflow direction | Air intake from left and front, air exhaustion from right | 
| PoE | Not supported | 
| Certification | EMC certification Safety certification Manufacturing certification | 

 
     
             .
.
    