APC Smart-UPS 3000VA LCD RM 2U 230V with SmartConnect
SKU
SMT3000RMI2UC
In stock
Line-interactive topology, 3000VA/1800W output power capacity, 230V nominal input and output voltage, 8 IEC C13 outlets, Automatic Voltage Regulation (AVR), Cold-start capable, SmartConnect port, USB and Serial communication, Graphic LCD, Pure sine wave output on battery, Single switched outlet group, Predictive replace battery date, Configurable for 220 / 230 / 240 nominal output voltage, Surge energy rate: 750 J (SMT3000RMI2UC)
Categories: Default Category, Power, UPS, APC
Output power capacity - 2.7kWatts / 3.0kVA
Rack Height - 2U
Output Connections
(3) IEC Jumpers (Battery Backup)
(8) IEC 320 C13 (Battery Backup)
(1) IEC 320 C19 (Battery Backup)
Nominal Output Voltage - 230V
Nominal Input Voltage - 230V
Input Connections - BS1363A British, IEC 320 C20, Schuko CEE 7 / EU1-16P
Cord Length - 2meters
APC Smart-UPS 3000VA Rack Mount, LCD 3000VA, 230V with SmartConnect Port
Intelligent and efficient network power protection from entry level to scaleable runtime. Ideal UPS for servers, point-of-sale, routers, switches, hubs and other network devices.
Includes: Documentation CD, Rack mounting hardware, Rack mounting support rails, USB cable
- Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.
- Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.
- Provides notification of changing utility power and UPS power conditions
- Automatically starts up the connected equipment upon the return of utility power.
- Periodic battery self-test ensures early detection of a battery that needs to be replaced.
- Provides early-warning fault analysis on batteries enabling timely preventive maintenance
- Gives higher application availability by correcting low and high voltage conditions without using the battery (not available on all models).
- Provides temporary battery power when the utility power is out.
- Warns when a battery is not available to provide backup power.
- Provides actual kilowatt hours of usage for energy conscious users.
- Gives higher application availability by correcting poor frequency and voltage conditions without using the battery.
- Patent-pending operating mode that bypasses unused electrical components in good power conditions to achieve very high operating efficiency without sacrificing any protection.
- Reduces utility costs, generates less heat.
- Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
- Maximizes battery performance, life, and reliability through intelligent, precision charging.
- Provides clear and accurate information in multiple languages with the ability to configure the UPS locally with easy to use navigation keys.
- Provide easy-to-read status of the unit and utility power conditions.
- Provides remote power management of the UPS over the network.
- Turn on/off, reboot or shut down select outlet groups to save dispatching technicians to remote locations (for UPSs with switched outlet groups).
- Provides early-warning fault analysis ensuring proactive component replacement.
- Dynamically provides the month and year when battery replacement is recommended to aide in long term maintenance planning.
- Simulates utility power to provide the highest degree of compatibility for active PFC (power factor corrected) servers and sensitive electronics.
- Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
- Customize network shutdown and reboot sequence of connected servers and UPSs.
- Provides management of the UPS via a serial port.
- Single outlet group that may be controlled separately from the UPS for discrete reboot of hung devices, sequenced on/off and non-critical load shedding.
- Innovative, easy to use remote monitoring feature that provides automatic notifications, firmware updates, and advanced support services.
- Enables centralized management via StruxureWare Data Center Expert.
- Prolongs battery life by regulating the charge voltage according to battery temperature.
- Provides management of the UPS via a USB port (not available on all models).
- Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
- Designed for harsh electrical environments to save battery life.
Smart-UPS Features & Benefits
Serviceability
User-replaceable batteries
Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair (MTTR)
Predictive failure notification.
Provides early-warning fault analysis ensuring proactive component replacement.
Resettable circuit breakers
Enables a quick recovery from overload events.
Battery failure notification
Provides early-warning fault analysis on batteries enabling timely preventive maintenance
Hot-swappable batteries
Ensures clean, uninterrupted power to protected equipment while batteries are being replaced
Safety
Safety-agency approved
Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.
Marketing features
Low operating and maintenance costs with high efficiency, proven reliability and intelligent battery management
Patented green operating mode achieves efficiencies over 97%. Smart-ups was the first network UPS to be Energy Star certified. Intelligent battery management, pioneered by APC, maximizes battery performance and life through intelligent, precision temperature compensated charging. Dynamic battery replacement date indicator and automatic self tests insure battery reliability and warn in advance of needing replacement. Convenient, easy to connect, hot-swappable battery modules provide battery replacement without powering down. Designed and manufactured by APC for over 23 years, Smart-UPS is the world’s most trusted network UPS with over 25 million units sold.
Peace of mind that comes with full equipment compatibility and reliability of a leader
Provides pure sine wave output which is recommended by server manufacturers using active power factor corrected (PFC) power supplies. Safety agency tested and approved means that you can deploy Smart-UPS with confidence that they meet or exceed the industry’s most rigorous standards.
Save time with easy and convenient remote accessibility
Network manageable via serial, USB or optional ethernet. Includes Powerchute® Business Edition Software for convenient monitoring and control, safe operating system shutdown and innovative energy management capabilities.
Smarter productivity with ability to tailor to your specific application needs
Intuitive LCD interface provides clear information with the ability to configure the UPS locally with easy to use navigation keys. Over 15 different programmable settings including switched outlet group control allow for application specific settings, thresholds and notifications.
Avoids costly power problems by keeping your IT equipment and data safe and available
Network grade power conditioning protects from damaging surges and disruptive noise. Solid state automatic voltage regulation boosts low input voltage up to 30% and trims high voltage up to 12% without battery operation. Reliable battery back-up capacity to power through outages or gracefully shutdown systems
Manageability
Network manageable
Provides remote power management of the UPS over the network.
Serial connectivity
Provides management of the UPS via a serial port.
LED status indicators
Quickly understand unit and power status with visual indicators.
USB connectivity
Provides management of the UPS via a USB port (not available on all models).
Audible alarms
Provides notification of changing utility power and UPS conditions.
Availability
Intelligent battery management
Maximizes battery performance, life, and reliability through intelligent, precision charging.
Power conditioning
Protects connected loads from surges, spikes, lightning, and other power disturbances.
Boost and Trim Automatic Voltage Regulation (AVR)
Gives higher application availability by correcting low and high voltage conditions without using the battery (not available on all models).
Disconnected battery notification
Warns when a battery is not available to provide backup power.
Automatic restart of loads after UPS shutdown
Automatically starts up the connected equipment upon the return of utility power.
Automatic self-test
Periodic battery self-test ensures early detection of a battery that needs to be replaced.
Temperature-compensated battery charging
Prolongs battery life by regulating the charge voltage according to battery temperature.
Adaptability
Adjustable voltage sensitivity
Provides the ability to adapt the UPS for optimal performance in specific power environments or generator applications.
Adjustable voltage-transfer points
Maximizes useful battery life by widening the input voltage window or tightening the output voltage regulation.
Log In